info@labwan.co.in +91 9056603301 Mon–Sat: 9:00 AM – 6:00 PM
Spectrophotometer

LABWAN Atomic Absorption Spectrophotometer LAAS-5310

Model LAAS-5310 In Stock

An atomic absorption spectrophotometer designed for chemical laboratory analysis, quality assurance and control, and research applications. The instrument combines an optical system with automated gas control, background correction, flame atomization, and data-processing functions.

Get Quote Catalog Not Available
ISO 9001 Certified Service & Support
Key Features
  • Intelligent stray-light measurement and correction.
  • Optical noise reduction with automatic measurement and dynamic stray-light detection.
  • Internal lamp control technology for hollow-cathode lamp background correction.
  • Automated element-lamp adjustment system.
  • Gas-path electronic functional and modular design.
  • No-adjustment D-lamp holder.
  • Automatic gas-flow and pressure control.
  • Multiple background-correction methods.
  • Supports flame and flame-emission testing.
  • Optional graphite furnace, graphite-furnace auto-sampler, and hydride generator.

Specifications

Parameter Value
Instrument Type Single Beam Reflection Achromatic Optics System
Monochromator Aberration Corrected Czerny-Turner
Grating System 1200 line/mm
Characterization Area 40mm²
Scintillation Wavelength 250nm
Bandwidth 0.1, 0.2, 0.4, 1nm (4 step auto switching)
WL Range 190-900nm
WL Accuracy ±0.2nm
WL Repeatability ±0.1nm max
Resolution Min 3 lines (279.5 & 279.8 peak and Valley)
HCL Housing Standard 4 lamp turret (1 for measurement, 3 in warm-up mode)
Gas Control Automatic control & optimization (flow/pressure)
Safety Measures Gas leak check; prevention of gas release when flame dies out; prevention of flashback through pressure monitoring
Measurement Aberration-corrected Czerny-Turner mounting
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.006A/30min
Background Correction High speed self-reversal (BGC-SR) method; High speed D2 lamp method (BGC-D2)
Characteristic Concentration (Cu) 0.025 μg/ml max
Detection Limit (Cu) 0.004 μg/ml max
Precision RDS = 0.5%
Burner Air cooled Titanium
Nebulizer High-efficient Nebulizer
Spray Chamber Anticorrosion material
Safety Measures Flame fuel gas, power assisted gas abnormal pressure protection
Test Manner Flame, flame emission
Concentration Standard curve, standard addition, interpolation
Times of Repetitive Measurement 1-30 times, Average Value of A&C
Report Print parameters, date result
Dimension & Weight (Flame) 700×420×550 mm; 103 kg (approx.)
Power (Main Unit with Flame) AC 220 V ±10%, 50 Hz without sharp fluctuations
Working Temperature Range 10~30°C
Working Humidity Range 40%~85%